General Specifications and Rated Conditions
1238888 |
Vantage
Size |
|
Laser Tracker Vantage |
226(W) x 415(H) x 239.5(D) mm 8.90(W) x 16.34(H) x 9.45(D) in |
|
|
Power Supply/Communications Box |
322(L) x 68.5(W) x 43(H) mm 12.7(L) x 2.7(W) x 1.7(H) in |
|
Weight |
|
Laser Tracker |
13.4kg 29.5lbs |
Rated Conditions |
|
Measurement Envelope Distance |
|
|
80m (262.5ft) with select targets 60m (196.9ft) with Standard 1½” SMR 40m (131.2ft) with Standard ⅞” SMR 30m (98.4ft) with Standard ½” SMR 15m (49.2ft) with FARO
35m (114.8ft) with Standard 1½” SMR 35m (114.8ft) with Standard ⅞” SMR 30m (98.4ft) with Standard ½” SMR 15m (49.2ft) with FARO |
|
|
Range of horizontal angle Range of vertical angle |
360 degrees - infinite rotation 130 degrees (+77.9/-52.1) |
|
|
Temperature Range Operating |
Min -15°C, Max 50°C Min 5°F, Max 122°F |
Humidity Operating |
Min 0% RH, Max 95% RH non-condensing |
IP Rating |
IP52 |
Barometric Pressure Range Operating |
Min 225.50mmHG, Max 825.07mmHG Min 8.878inHG, Max 32.483inHG |
Elevation Operating |
-700m to 9000m (-2,297ft to 29,527ft) |
Ambient Light |
Direct exposure to sunlight or flash lamps may compromise performance. |
Voltage
Current
Frequency
Surge
Sag
Max Transient Voltages |
100 - 240VAC ± 10% 24VDC, 0-8.33A
2.3A (US), 1.1A (EU)
50/60Hz
1000V common, 500V differential, 1.25/50µs waveform
70% Nominal Voltage, 0.5s, 40% Nominal Voltage, 5.0s
1000 V common, 500v differential, 5/50 ns, 1 min waveform |
Probe Type Diameter
Reflector Type |
1½” (38.1mm), ⅞” (22.225mm),
Spherically Mounted Retroreflector (SMR) |
Sampling Strategy Acquisition time
Frequency |
1sec
1000points/sec |
Locations For Use | In wet condition |
Over Voltage Category | I for Laser Tracker |
Pollution Degree | 2 |
Limiting Conditions |
|
Storage Temperature Range |
Min -20°C, Max 70°C Min -4°F, Max 158°F |
Humidity Range |
Min 0% RH, Max 100% RH |
Barometric Pressure Range |
7500mmHg overpressure 295.276inHG overpressure |
FARO
Size |
|
FARO |
240(L) x110.0(W) x 141.5(D) mm 9.4(W) x 4.3(H) x 5.6(D) in |
|
Weight |
|
FARO |
885 g 1.95 lb |
Performance |
|
Accuracy (MPE) |
50μm + 5μm/m with 40mm stylus length 0.0037in + 0.00006in/ft with 1.97in stylus length |
Maximum Permissible Error (MPE) is per ISO 10360-10:2016 specification, reported as the radius of the minimum circumscribing sphere. |
|
Range |
Min 2.5m (8.2 ft) Max 15m (49.2 ft) |
|
|
System Sample Rate |
1,000 samples per second |
Lithium-Ion Battery |
Continuous usage 2-4 hours Typical usage 8+ hours |
On-Axis position to laser beam |
Pitch: ±25° Yaw: ±25° Roll: 360° |
Rated Conditions |
|
Temperature Range Operating |
Min -15°C, Max 40°C Min 5°F, Max 104°F |
Humidity Operating |
Min 0% RH, Max 95% RH non-condensing |
Elevation Operating |
-700m to 9000m (-2,297ft to 29,527ft) |
IP Rating |
IP52 |